Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

Event ID 4999 is logged when an administrator deletes a mailbox store on an Exchange Server 2007 Service Pack 1-based server


View products that this article applies to.

Symptoms

On a computer that is running Exchange Server 2007 Service Pack 1 (SP1), an administrator deletes a store that was being replicated by using Standby Continuous Replication (SCR). However, if the administrator does not remove the storage group that hosted the store or the administrator does not disable SCR before the administrator removes the store, the Microsoft Exchange Replication service crashes intermittently. Additionally, the following event is logged in the Application log:
Log Name:      Application 
Source:        MSExchange Common 
Event ID:      4999 
Description: 
Watson report about to be sent to dw20.exe for process id: <ID>, with parameters: E12, c-RTL-AMD64, <version>, M.E.C.ReplayService,  M.E.C.Replay, M.E.C.R.ScrReplayConfiguration.ConfigurationPathConflict, System.IndexOutOfRangeException, 63b0, <version>.   ErrorReportingEnabled: True
 
more information from the crash
+  $exception {System.IndexOutOfRangeException: Index was outside the bounds of the array. 
   at Microsoft.Exchange.Cluster.Replay.ScrReplayConfiguration.ConfigurationPathConflict(Dictionary`2 currentConfigurations, String&  field) 
   at Microsoft.Exchange.Cluster.ReplayService.ReplayManager.AddScrTargetConfigurations(List`1 ScrTargetConfigurations, Dictionary`2  currentConfigurations, Int32 limit) 
   at Microsoft.Exchange.Cluster.ReplayService.ReplayManager.GetCurrentConfigurations(Boolean& targetReplicaInstanceWasNotStarted) 
   at Microsoft.Exchange.Cluster.ReplayService.ReplayManager.GetCurrentConfigurations(Boolean calledForShutdown, Boolean&  targetReplicaInstanceWasNotStarted) 
   at Microsoft.Exchange.Cluster.ReplayService.ReplayManager.ConfigurationUpdaterInternal(Boolean calledForShutdown, Boolean&  targetReplicaInstanceWasNotStarted) 
   at Microsoft.Exchange.Cluster.ReplayService.ReplayManager.ConfigurationUpdater(Object calledForShutdownObject) 
   at System.Threading._TimerCallback.TimerCallback_Context(Object state) 
   at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state) 
   at System.Threading._TimerCallback.PerformTimerCallback(Object state)} System.Exception {System.IndexOutOfRangeException}

↑ Back to the top


Resolution

To resolve this problem, install Update Rollup 9 for Exchange 2007 Service Pack 1. For more information about Update Rollup 9 for Exchange Server 2007 Service Pack 1, see the following Exchange Help topic: For more information about how to obtain the latest Exchange service pack or update rollup, see the following Exchange Help topic:

↑ Back to the top


Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

↑ Back to the top


Keywords: KB968111, kbsurveynew, kbqfe, kbfix, kbexpertiseadvanced

↑ Back to the top

Article Info
Article ID : 968111
Revision : 2
Created on : 7/17/2009
Published on : 7/17/2009
Exists online : False
Views : 298