Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

XCON: Dynamic Remote Access Service Connection Does Not Work and RPCPing Returns Error Message "-RpcServerUseProtSeqEp, status 0xE"


View products that this article applies to.

This article was previously published under Q257308

↑ Back to the top


Symptoms

Dynamic Remote Access Service (RAS) dials the receiving server, but the connection may be terminated (the other server hangs up) and no mail is transferred. When you run the Rpingc32 utility against the Rpings utility, the ping does not work and the following error message is displayed:
-RpcServerUseProtSeqEp returned a status 0xE

↑ Back to the top


Cause

The hexadecimal value 0xE translates to a decimal value of 14. If you type the following command at a command prompt
NET HELPMSG 14
the Microsoft Windows NT error code is translated as "Not enough storage is available to complete this operation."

↑ Back to the top


Resolution

To resolve this issue, increase the amount of random access memory (RAM) on the receiving server.

↑ Back to the top


More information

For additional information, click the article number below to view the article in the Microsoft Knowledge Base:
175496� XCON: Using RPCPing to Troubleshoot MTA Connections

↑ Back to the top


Keywords: KB257308, kbprb

↑ Back to the top

Article Info
Article ID : 257308
Revision : 6
Created on : 10/28/2006
Published on : 10/28/2006
Exists online : False
Views : 293