While resuming from hibernation (S4), Windows Server 2003 may crash on some high-end servers with an HBA installed


View products that this article applies to.

Source: Microsoft Support

↑ Back to the top


Rapid publishing

RAPID PUBLISHING ARTICLES PROVIDE INFORMATION DIRECTLY FROM WITHIN THE MICROSOFT SUPPORT ORGANIZATION. THE INFORMATION CONTAINED HEREIN IS CREATED IN RESPONSE TO EMERGING OR UNIQUE TOPICS, OR IS INTENDED SUPPLEMENT OTHER KNOWLEDGE BASE INFORMATION.

↑ Back to the top


Symptom

On some new high-end servers with an HBA installed, the system�may crash�while resuming from hibernation.

↑ Back to the top


Cause



This issue can occur in Windows Server 2003 when the Max Payload Size for the HBA is set to a value other than the default value.� This is usually done by the system BIOS.

When the HBA resumes from the low power state induced by transistioning to hibernation, the Max Payload Size returns to its default value.� Because the BIOS is expecting a different Max Payload Size value from the HBA, the system may crash.

↑ Back to the top


Disclaimer

MICROSOFT AND/OR ITS SUPPLIERS MAKE NO REPRESENTATIONS OR WARRANTIES ABOUT THE SUITABILITY, RELIABILITY OR ACCURACY OF THE INFORMATION CONTAINED IN THE DOCUMENTS AND RELATED GRAPHICS PUBLISHED ON THIS WEBSITE (THE �MATERIALS�) FOR ANY PURPOSE. THE MATERIALS MAY INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS AND MAY BE REVISED AT ANY TIME WITHOUT NOTICE.

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, MICROSOFT AND/OR ITS SUPPLIERS DISCLAIM AND EXCLUDE ALL REPRESENTATIONS, WARRANTIES, AND CONDITIONS WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO REPRESENTATIONS, WARRANTIES, OR CONDITIONS OF TITLE, NON INFRINGEMENT, SATISFACTORY CONDITION OR QUALITY, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE MATERIALS.

↑ Back to the top


Keywords: kbnosurvey, kbarchive, kbrapidpub, kbnomt, KB969916

↑ Back to the top

Article Info
Article ID : 969916
Revision : 1
Created on : 1/14/2015
Published on : 1/14/2015
Exists online : False
Views : 295