Action

When adding a Medium Changer Tape Backup device to a Windows Server 2003 or Server 2008 system, the system's device manager may not show all components of the device: the tape drive(s) or the changer (robotics).�

↑ Back to the top


Result

Portions of the device are not visible in the device manager.� As such, the Removable Storage service based applications, including Tape Backup software,�may not be able to fully utilize the Medium Changer.�

↑ Back to the top


Cause



The HBA (host bus adapter) the Medium Changer is connected to is using Storport compatible drivers and the Medium Changer uses a non_hierarchical scsi REPORT_LUNS structure.� When a seemingly valid REPORT_LUNS structure is returned from the target device, it will be used to determine the LUNs available to the operating system. If the target uses a non-hierarchical REPORT_LUNS structure, storport will still use it to identify the LUNs, even though it does not understand the format. This can result in LUN 0 (the tape drive) being correctly identified , but not LUN 1 (the robotic changer device), so it does not show up in device manager or RSM (Removable Storage Manager).

This can be a PCI-E SCSI host bus adapter, or other slot� or interconnect technology.� For example: a Fibre-Channel HBA in a PCI slot.�







↑ Back to the top


Resolution

Install Scsiport drivers for the HBA rather then Storport.�

↑ Back to the top


Disclaimer

MICROSOFT AND/OR ITS SUPPLIERS MAKE NO REPRESENTATIONS OR WARRANTIES ABOUT THE SUITABILITY, RELIABILITY OR ACCURACY OF THE INFORMATION CONTAINED IN THE DOCUMENTS AND RELATED GRAPHICS PUBLISHED ON THIS WEBSITE (THE �MATERIALS�) FOR ANY PURPOSE. THE MATERIALS MAY INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS AND MAY BE REVISED AT ANY TIME WITHOUT NOTICE.

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, MICROSOFT AND/OR ITS SUPPLIERS DISCLAIM AND EXCLUDE ALL REPRESENTATIONS, WARRANTIES, AND CONDITIONS WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO REPRESENTATIONS, WARRANTIES, OR CONDITIONS OF TITLE, NON INFRINGEMENT, SATISFACTORY CONDITION OR QUALITY, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE MATERIALS.

↑ Back to the top


Keywords: kbnomt, kbrapidpub, KB967736

↑ Back to the top

Article Info
Article ID : 967736
Revision : 1
Created on : 2/10/2009
Published on : 2/10/2009
Exists online : False
Views : 413