Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

Run-Time Error '91': Object Variable or With Block Variable Not Set, Followed by Error 59999 - Application-defined or Object-defined Error


Symptoms

"Runtime error '91': Object variable or With block variable not set" "Error 59999 - Application-defined or object-defined error"These errors occur when generating a report to XML/Enhanced XML.

↑ Back to the top


Cause

Insufficient permissions on the FRxXMLTag.XML file in the FRx directory.

↑ Back to the top


Resolution

Resolution Log into Windows as an administrative user. Browse to the FRx directory in Windows Explorer. Right-click on the FRxXMLTag.XML file, select Properties, and then click the Security tab. Add the group Everyone, select Full Control, then click OK.

↑ Back to the top


References

↑ Back to the top


Keywords: kb

↑ Back to the top

Article Info
Article ID : 966275
Revision : 6
Created on : 9/2/2020
Published on : 9/2/2020
Exists online : False
Views : 141