Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

Run-Time Error '429': ActiveX Component Can't Create Object


Symptoms

"Runtime error '429': ActiveX component can't create object" This error occurs when starting the FDM Load, FDM Import Wizard, or when opening a .dts package.

↑ Back to the top


Cause

One or more DLL files failed to register during the installation of the FDM Load or FDM Import Wizard program.

↑ Back to the top


Resolution

Resolution Register sqldmo.dll, axscphst.dll, dtsffile.dll, dtspkg.dll, and dtspump.dll files, all of which are located in the C:\\Program Files\\Microsoft SQL Server\\80\\Tools\\Binn folder.

↑ Back to the top


References

↑ Back to the top


Keywords: kb

↑ Back to the top

Article Info
Article ID : 966109
Revision : 6
Created on : 9/2/2020
Published on : 9/2/2020