Error 3704 Operation is not Allowed when the Object is Closed


Symptoms

"Error 3704 operation is not allowed when the object is closed" "Queing catalog failed"These errors occur when generating a report.

↑ Back to the top


Cause

A corrupt FRxque32.mdb file.

↑ Back to the top


Resolution

Exit out of the FRx Report Server. Delete the FRxque32.mdb file located in the Sysdata directory. Re-open the Report Server.This actionwill recreate the FRxQue32.mdb file from the template, which will allow you to send reports to the Queue without error.