Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

Error 40002 07S01: [Microsoft][ODBC SQL Server Driver]Invalid use of Default Parameter


Symptoms

"Error 40002 07S01: [Microsoft][ODBC SQL Server Driver]Invalid use of default parameter" when setting a company as default.

↑ Back to the top


Cause

This error is caused when the DirectLink file is not properly registered on the thin client workstation.

↑ Back to the top


Resolution

  1. Verify that the server installation is upgraded to the latest service pack and run FRxreg.exe from the server FRx directory. If this does not resolve the issue, proceed to step 2.
  2. Browse to the main Microsoft FRx directory through Windows Explorer and locate the FSxxxx.dll file where the xxxx is GL specific. (i.e.: FSFRL60.dll for FDM),
  3. Unregister the FSxxxx.dll from the local workstation.
  4. Manually register the Server FSxxxx.dll on the thin client workstation. For information on how to register dll files, see 8252 : Registering DLL Files
  5. Launch FRx Designer and set a company as default.

↑ Back to the top


References

↑ Back to the top


Keywords: kb, misc_migrate_32718

↑ Back to the top

Article Info
Article ID : 964441
Revision : 4
Created on : 4/13/2018
Published on : 4/13/2018
Exists online : False
Views : 91