On a computer that is running Microsoft BizTalk Server 2006 R2, the following problems are fixed in this cumulative hotfix package:Problem 1
If you set output values on digital input/output (I/O) ports that are built into radio frequency identification (RFID) readers, high latency occurs. For example, setting a color on a light stack may take a long time. This problem causes either a delay in operator tasks, or incorrect results in automated operations.Problem 2
When the BizTalk RFID service is restarted while the service is receiving tag events from devices, some tag events are lost. In this situation, the loss of tag events occurs for a short time.Problem 3
Device Discovery in Microsoft BizTalk RFID does not support the following two scenarios. After you apply the hotfix that this is described in this article, Device Discovery supports these scenarios correctly.Scenario 1
Consider the following scenario:- You are using RFID devices that use Dynamic Host Configuration Protocol (DHCP) to obtain IP addresses.
- After the DHCP lease expires and the lease is renewed, two devices (device 1 and device 2) swap IP addresses.
Scenario 2
BizTalk RFID treats different handheld devices that are running BizTalk RFID Mobile as the same device. For example, consider the following scenario:- You are using ActiveSync.
- You dock handheld device 1.
- Device 1 has the parameters ID1-N1-C1.Note The parameters ID1-N1-C1 represent the Device ID, the Name, and the Connection Information.
- You add device 1 to BizTalk RFID.
- You undock device 1 and then you dock another device (device 2).
Problem 4
The logging information is not written to one or more of the log files that are stored in the following folders:- Microsoft BizTalk RFID\Process
- Microsoft BizTalk RFID\Provider
- Microsoft BizTalk RFID\Services
This problem may occur if a third-party tool or a custom tool has an open file handle to any RFID log file when the log file rotation starts. If a third-party tool or a custom tool has an open handle to an RFID log file when the log file rotation starts, the logging information is written to the cache. However, the logging information is not written to the log file as expected. Therefore, the log file is empty.
For more information about the log file rotation feature in BizTalk RFID, see the "More Information" section.
Problem 5
You use a Microsoft Office Excel workbook as an external data source to print labels in the RFID Print Label wizard. However, the mapped data fields do not print correctly. For example, only the data that is in the last row of the workbook is included on the printed labels.Problem 6
In Microsoft BizTalk Server 2006 R2 Branch Edition, you try to add a new device and you receive an error message that resembles the following:The specified device operation failed as the current number of configured devices in the RFID store is equal to or greater than the maximum allowed number of configured devices (20) for your edition of Microsoft BizTalk RFID. Check if you can delete any devices that are no longer in use or if you can upgrade to a higher edition of Microsoft BizTalk RFID.