FIX: Error messages may be logged when you use BizTalk Accelerator for RosettaNet 3.0 or for RosettaNet 3.5


View products that this article applies to.

Symptoms

Consider the following scenario:
  • You install Microsoft BizTalk Server 2004 and BizTalk Accelerator for RosettaNet 3.0.
  • Or, you install Microsoft BizTalk Server 2006 R2 and BizTalk Accelerator for RosettaNet 3.5.
When you use Microsoft BizTalk Accelerator for RosettaNet 3.0 or for RosettaNet 3.5, error messages that resemble the following may be logged in the Application log.
Error message 1
Event Type: Error
Event Source: XLANG/s
Event Category: None
Event ID: 10034
Description:
Uncaught exception (see the 'inner exception' below) has suspended an instance of service 'Microsoft.Solutions.BTARN.PublicInitiator.PublicInitiatorProcess(89d9a4fa-4483-6e0e-e96a-3d482354c83a)'.
The service instance will remain suspended until administratively terminated.
InstanceId: 30333094-a453-402e-a20b-e8268e79dca4
ShapeId: 27605986-0b05-4762-8a12-0912f9d96e61
Exception thrown from: segment 11, progress 6
Inner exception: Timeout expired. The timeout period elapsed prior to obtaining a connection from the pool. This may have occurred because all pooled connections were in use and max pool size was reached.

Exception type: InvalidOperationException
Source: System.Data
Target Site: System.Data.SqlClient.SqlInternalConnection GetPooledConnection(System.Data.SqlClient.SqlConnectionString, Boolean ByRef)
Help Link:
The following is a stack trace that identifies the location where the exception occured
at System.Data.SqlClient.SqlConnectionPoolManager.GetPooledConnection(SqlConnectionString options, Boolean& isInTransaction)
at System.Data.SqlClient.SqlConnection.Open()
at Microsoft.Solutions.BTARN.Shared.SqlHelper.ExecuteReader(String connectionString, CommandType commandType, String commandText, SqlParameter[] commandParameters)
at Microsoft.Solutions.BTARN.Shared.SqlHelper.ExecuteReader(String connectionString, String spName, Object[] parameterValues)
at Microsoft.Solutions.BTARN.Shared.ActivityTracking.UpdateStatusOfActivity(String activityID, ActivityTrackingStatusCodes newStatus)
at Microsoft.Solutions.BTARN.PublicInitiator.PublicInitiatorProcess.segment11(StopConditions stopOn)
at Microsoft.XLANGs.Core.SegmentScheduler.RunASegment(Segment s, StopConditions stopCond, Exception& exp)
Error message 2
Event Type: Error
Event Source: BizTalk Accelerator for RosettaNet
Event Category: None
Event ID: 0
Description:
Source module:
PublicResponderProcess

Correlation information:
PIP Code: 0C1
PIP Version: V01.00
PIP InstanceID: 0a28f375f70dd0e700734748
SourcePartnerName: SOURCE PARTNER NAME
DestinationPartnerName: DESTINATION PARTNER NAME
Description:
Timeout expired. The timeout period elapsed prior to obtaining a connection from the pool. This may have occurred because all pooled connections were in use and max pool size was reached.
Note In the second error message, the values for PIP Code, PIP Version, PIP InstanceID, SourcePartnerName, and DestinationPartnerName may be different.

↑ Back to the top


Resolution

Hotfix information

There are two versions of this hotfix:
  • BizTalk Accelerator for RosettaNet 3.0
  • BizTalk Accelerator for RosettaNet 3.5
A supported hotfix is now available from Microsoft. However, it is intended to correct only the problem that is described in this article. Apply it only to systems that are experiencing this specific problem.

To resolve this problem immediately, contact Microsoft Customer Support Services to obtain the hotfix. For a complete list of Microsoft Customer Support Services telephone numbers and information about support costs, visit the following Microsoft Web site:Note In special cases, charges that are ordinarily incurred for support calls may be canceled if a Microsoft Support Professional determines that a specific update will resolve your problem. The usual support costs will apply to additional support questions and issues that do not qualify for the specific update in question.

Prerequisites

You must have Microsoft BizTalk Server 2004 and BizTalk Accelerator for RosettaNet 3.0 installed to apply the RosettaNet 3.0 hotfix. You must also apply hotfix KB922821 before you apply the RosettaNet 3.0 hotfix. For more information about this hotfix, click the following article number to view the article in the Microsoft Knowledge Base:
922821� FIX: Error message when you process CIDX version 4.0-based documents by using the BizTalk Accelerator for RosettaNet: "Token Invalid"
You must have Microsoft BizTalk Server 2006 R2 and BizTalk Accelerator for RosettaNet 3.5 installed to apply the RosettaNet 3.5 hotfix.

Restart requirement

You do not have to restart your computer after you apply this hotfix. However, you must restart the BizTalk host instances.

Hotfix replacement information

This hotfix does not replace any other hotfixes.

File information

The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.
RosettaNet 3.0
Collapse this tableExpand this table
File nameFile versionFile sizeDateTimePlatform
Microsoft.solutions.btarn.shared.dll3.0.752.0123,95206-Nov-200716:48x86
RosettaNet 3.5
Collapse this tableExpand this table
File nameFile versionFile sizeDateTime
Microsoft.Solutions.BTARN.Shared.dll3.5.309.0123,95201-Feb-200808:11:40
Note Because of file dependencies, the most recent hotfix that contains these files may also contain additional files.Note This hotfix updates components that are used by BizTalk Accelerator for RosettaNet orchestrations. Therefore, make sure that any currently running orchestrations are complete before you install this hotfix.

↑ Back to the top


Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

↑ Back to the top


More information

For more information, click the following article numbers to view the articles in the Microsoft Knowledge Base:
824684� Description of the standard terminology that is used to describe Microsoft software updates
922821� FIX: Error message when you process CIDX version 4.0-based documents by using the BizTalk Accelerator for RosettaNet: "Token Invalid"

↑ Back to the top


Keywords: kbexpertiseinter, kbfix, kbqfe, KB944749

↑ Back to the top

Article Info
Article ID : 944749
Revision : 3
Created on : 10/8/2011
Published on : 10/8/2011
Exists online : False