The MQSeries Adapter no longer retrieves messages from a clustered MQSeries queue manager when the queue manager fails over to a different cluster node
This article helps you work around the problem where MQSeries Adapter no longer retrieves messages from a clustered MQSeries queue manager when the queue manager fails over to a different cluster node.
Original product version: BizTalk Server 2020, BizTalk Server 2016, BizTalk Server 2013, BizTalk Server 2010, BizTalk Server 2009
Original KB number: 893059
You configure the Microsoft BizTalk Server Adapter for MQSeries to receive messages from a clustered MQSeries queue manager. If the queue manager fails over to a different cluster node, the MQSeries Adapter no longer retrieves messages from the clustered queue. When this behavior occurs, the following event is logged in the Application log:
Event Type: Warning
Event Source: BizTalk Server 20xx
Event Category: BizTalk Server 20xx
Event ID: 5740
Date: 12/31/2006 Time: 11:12:13 AM
User: N/A
Computer:
Description: The adapter "MQSeries" raised an error message. Details "Error encountered on opening Queue Manager name = MYQMNAME Reason code = 2059.".
Note
In this log entry, <20xx>
represents the actual version number, and <MYQMNAME>
represents the actual Queue Manager name.
To work around this issue, create a scheduled task on both nodes. To do this, follow these steps:
On the active node, open Services.msc. You should see two MSDTC services listed: One that is local and has no GUID, and one that is clustered and has a GUID.
At an elevated command prompt, run the following command:
sc queryex | find /I "Transaction"
The command output contains the GUID that you must use for the script in this procedure. The GUID:
Distributed Transaction Coordinator (01234567-89ab-cdef-0123-456789abcdef)
Save the following code to a file, and name the file Shutdownmqadapter.vbs. You can save the file to any disk other than the quorum disk.
Note
In this code, the indicated GUID (
01234567-89ab-cdef-0123-456789abcdef
) is a placeholder. Replace this GUID with the actual clustered MSDTC GUID that you noted in step 2.Option Explicit On Error Resume Next Dim sComputerName, oWMIService, colRunningServices, oService, colProcessList, objProcess If Wscript.Arguments.Count = 0 Then sComputerName = "." Call ServStat Wscript.Quit End If Sub ServStat Set oWMIService = GetObject("winmgmts:" _ & "{impersonationLevel=impersonate}!\\" & sComputerName& "\root\cimv2") Set colRunningServices = oWMIService.ExecQuery _ ("Select * from Win32_Service where DisplayName='Distributed Transaction Coordinator (01234567-89ab-cdef-0123-456789abcdef)'") For Each oService in colRunningServices 'Wscript.Echo oService.DisplayName & VbTab & oService.State If (oService.State="Stopped") Then 'Wscript.Echo "Stopped" 'find the dllhost Set colProcessList = oWMIService.ExecQuery ("SELECT * FROM Win32_Process WHERE Name = 'DLLHOST.EXE'") For Each objProcess in colProcessList If inStr(objProcess.CommandLine, "C691D827-19A0-42E2-B5E8-2892401481F5")>0 Then 'Wscript.Echo objProcess.ProcessId Dim objShell Set objShell = CreateObject("WScript.Shell") objShell.Run "cmd /k taskkill /F /PID " & objProcess.ProcessId & "& exit" WScript.Quit End If Next End If Next End Sub
Select Start, type task, and then select Task Scheduler in the results list.
In Task Scheduler, select Action > Create Basic Task.
Run through the wizard screens to create a scheduled task that runs the Shutdownmqagent.vbs file daily.
Note
For the 6 step, set the schedule to start at midnight and repeat every 1 minute for 24 hours.
Earlier BizTalk versions may have a different MQSAgent COM+ GUID. They may have 6D06157A-730B-4CB3-BD11-D48AC6B8A4BB
instead of C691D827-19A0-42E2-B5E8-2892401481F5
. Therefore, you may have to change the existing script after you upgrade the product.
Even if the IBM MQ queue manager is running as a clustered resource in a failover cluster role, you should not cluster the MQSAgent COM+ application. This is because DLLHost.exe, which is running the COM+ application, is not cluster-aware. You must have the MQSAgent COM+ application installed and configured individually on both nodes.
To ensure high availability, make sure that you use both the clustered IBM MQ queue manager resource and the clustered MSDTC resource in the same cluster role together with the monitoring script from the Workaround section.