Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

Schema field promotion changes do not take effect until the BizTalk Server Application Service is restarted


View products that this article applies to.

Symptoms

After you modify a deployed schema and then re-deploy the schema, changes to the schema do not take effect and field promotion changes are not seen.

↑ Back to the top


Resolution

The Microsoft BizTalk Server Application Service must be stopped and then restarted after the modified schema is redeployed.

↑ Back to the top


Status

This behavior is by design.

↑ Back to the top


More information

When a deployed schema is redeployed, any changes in the assembly of the schema are promulgated to the Global Assembly Cache (GAC). The updated assembly is loaded into the default application domain (AppDomain) from the GAC. If the assembly already exists in the default AppDomain, the assembly in the AppDomain is not updated until the AppDomain is recycled by restarting the BizTalk Server Application Service.

↑ Back to the top


Keywords: KB835865, kbprb

↑ Back to the top

Article Info
Article ID : 835865
Revision : 2
Created on : 9/25/2006
Published on : 9/25/2006
Exists online : False
Views : 552