Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

"Internal Error 500" Error Message When You Try to Connect to the Microsoft Project Central Web Site


View products that this article applies to.

Symptoms

When you install Microsoft Project Central Server 2000 on a Windows Server 2003-based system, the Microsoft Project Central Web site is not available. When you try to connect to the logon page, you receive an error message that is similar to the following:
Internal Error 500: The server encountered an unexpected condition which prevented it from fulfilling the request.

↑ Back to the top


Cause

This issue occurs because, by default, the Enable Parent Paths option for the Microsoft Project Central virtual directory is turned off in Windows Server 2003. This change (from earlier versions of Windows) is part of a general security enhancement in Windows Server 2003.

↑ Back to the top


Resolution

To resolve this issue, turn on the Enable Parent Paths option for the Microsoft Project Central virtual directory. To do this, follow these steps:
  1. Navigate to the Microsoft Project Central folder in the Microsoft Internet Information Services (IIS) Management Console.
  2. Right-click the Microsoft Project Central folder, and then click Properties.
  3. Click the Virtual Directory tab.
  4. Click Configuration, and then click the Options tab.
  5. Click to select the Enable Parent Paths check box.

↑ Back to the top


Keywords: KB816709, kbprb, kberrmsg

↑ Back to the top

Article Info
Article ID : 816709
Revision : 5
Created on : 10/30/2006
Published on : 10/30/2006
Exists online : False
Views : 281