Event ID 25075 on Mediation server about SipHealthMonitor not configured in Skype for Business Server 2019


View products that this article applies to.

Symptoms

When you deploy Microsoft Skype for Business Server 2019 together with a stand-alone Mediation server pool, the following event ID 25075 is logged on the Mediation server:
Log Name:      Lync Server
Source:        LS Mediation Server
Date:          DateTime
Event ID:      25075
Task Category: (1030)
Level:         Warning
Keywords:      Classic
User:          N/A
Computer:      ComputerName
Description:
Mediation Server encountered an invalid setting that has been ignored.

Setting: Mediation Server Front End side SipHealthMonitor port not configured.  Health monitor is disabled.
Reason: N/A

Cause: Settings configured incorrectly.
Resolution:
Reconfigure the specified setting.
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
  <System>
    <Provider Name="LS Mediation Server" />
    <EventID Qualifiers="33798">25075</EventID>
    <Level>3</Level>
    <Task>1030</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime="SystemTime" />
    <EventRecordID>397</EventRecordID>
    <Channel>Lync Server</Channel>
    <Computer>ComputerName</Computer>
    <Security />
  </System>
  <EventData>
    <Data>Mediation Server Front End side SipHealthMonitor port not configured.  Health monitor is disabled.</Data>
    <Data>N/A</Data>
  </EventData>