Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

Update Rollup 6 for System Center 2012 R2 Operations Manager


View products that this article applies to.

Introduction

This article describes the issues that are fixed in Update Rollup 6 for Microsoft System Center 2012 R2 Operations Manager. Additionally, this article contains the installation instructions for Update Rollup 6 for System Center 2012 R2 Operations Manager.

↑ Back to the top


Issues that are fixed in this update rollup

Operations Manager

  • The "Remove-DisabledClassInstance" Windows PowerShell command times out without completing

    The cmdlet takes lots of time to complete in large SCOM installations and sometimes times out without completing its work. This is fixed by optimizing the query that is used for deletion. 

  • Duplicate closed alerts

    The Find option in a message view sometimes gives results of the current search together with the results from previous searches. This occurs because of an update issue in the grid and is fixed so that values are displayed that correspond only to the current search. 

  • Topology widget objects lose location when they are opened in a console that has a different locale and decimal format

    Topology widgets that are created in one locale but are viewed from another locale display an incorrect location because of the widget's inability to interpret locale-specific formatting. This issue is fixed, and users can now create and view topology widgets from different locales.

  • WebConsole Details widget does not display anything

    When you click a message in the Alert widget, the details of the message are not displayed in the details widget on WebConsole. This issue is fixed by fixing the XAML page of the details widget. The XAML page was preventing the data from being displayed on the page.

  • Top 10 Performance widgets (WebConsole) are sometimes empty

    The Top 10 Performance widgets (WebConsole) are sometimes empty because of a performance issue. This issue was fixed in Update Rollup 3 through an MPB file that requires a manual import. Because many users missed importing the MPB, a fix is included in this update rollup as an SQL query update.

  • Problem with decoding SCOM trace log files

    Sometimes Operations Manager trace logs do not decode but generate the error "Unknown(X ): GUID=XXX (No Format Information found)." This occurs because the latest TMF files that contain formatting information for the related traces are missing. All TMF files are updated to make sure that traces are formatted correctly.

Unix/Linux Management Pack

  • JEE: WebLogic 12.1.3 servers on Linux or Solaris are not discovered

    WebLogic 12cR1 Rel3 Java Application Servers that are installed on Linux and Solaris are not discovered.

    Note The UNIX or Linux agent must be updated after you install the Management Pack update to resolve this issue.

    Relevant log messages:

    /var/opt/microsoft/scx/scx.log

    2015-02-04T15:28:18,797Z
    Trace [scx.core.common.pal.system.appserver.appserverenumeration:379:15739:139715041470400] Weblogic process does not contain the 'platform.home' or 'weblogic.system.BootIdentityFile' commandline argument.

    2015-02-04T15:28:18,797Z
    Trace [scx.core.common.pal.system.appserver.appserverenumeration:462:15739:139715041470400] Merging previously known instances with current running processes


  • In rare cases, lots of omiagent processes may be observed on a UNIX or Linux computer

    If a single instance of data that is returned by an OMI provider is larger than 64 kilobytes (KB), the omiagent process becomes unresponsive, and additional omiagent processes are created. This issue can occur on a managed UNIX- or Linux-based computer if a rule or monitor returns an instance of data larger than 64 KB. This is most likely to be seen when a custom shell command or script rules return lots of data in StdOut.

    Note After you upgrade the Operations Manager UNIX/Linux agent to the version that is contained in this Management Pack update, an instance that exceeds 64 KB will be truncated and will generate the following message in the scx.log file. You can use the log message to identify and change the workflow that is returning too much data.

    ExecuteCommand: Exceeded maximum output size for provider (64k), output truncated. Monitoring will not be reliable! Command executed: "


  • The SSLv3 protocol cannot be disabled in OpenSSL as used by the UNIX and Linux agents

    With this update, you can now disable the SSLv3 protocol for the Operations Manager UNIX and Linux agents. You can do this by adding a property to omiserver.conf (/etc/opt/microsoft/scx/conf). If SSLv3 is disabled, the UNIX and Linux agent will reject connections that cannot be negotiated by using TLS encryption. If SSLv3 is enabled (this is the default configuration), SSLv3 will be used only if TLS encryption cannot be negotiated.

    omiserver.conf options for configuration SSLv3

    PropertyDescription
    NoSSLv3=true|falseEnable/Disables use of SSLv3 

↑ Back to the top



How to obtain and install Update Rollup 6 for System Center 2012 R2 Operations Manager

Download information

Update packages for Operations Manager are available from Microsoft Update or by manual download from the Microsoft Update Catalog.

Microsoft Update
To obtain and install an update package from Microsoft Update, follow these steps on a computer that has an Operational Manager component installed:
  1. Click Start, and then click Control Panel.
  2. In Control Panel, double-click Windows Update.
  3. In the Windows Update window, click Check Online for updates from Microsoft Update.
  4. Click Important updates are available.
  5. Select the Update Rollup package, and then click OK.
  6. Click Install updates to install the update package.
Manual download of the update packages
Go to the following website to manually download the update packages from the Microsoft Update Catalog:


↑ Back to the top


Installation instructions
Installation notes
  • This update rollup package is available from Microsoft Update in the following languages:
    • Chinese Simplified (CHS)
    • Japanese (JPN)
    • French (FRA)
    • German (DEU)
    • Russian (RUS)
    • Italian (ITA)
    • Spanish (ESN)
    • Portuguese (Brazil) (PTB)
    • Chinese Traditional (CHT)
    • Korean (KOR)
    • Czech (CSY)
    • Dutch (NLD)
    • Polish (POL)
    • Portuguese (Portugal) (PTG)
    • Swedish (SWE)
    • Turkish (TUR)
    • Hungarian (HUN)
    • English (ENU)
    • Chinese Hong Kong (HK)


  • Some components are multilanguage, and the updates for these components are not localized.
  • You must run this update rollup as an administrator.
  • If you do not want to restart the computer after you apply the console update, close the console before you apply the update for the console role.
  • To start a new instance of Microsoft Silverlight, clear the browser cache in Silverlight, and then restart Silverlight.
  • Do not install this update rollup package immediately after you install the System Center 2012 R2 server. Otherwise, the Health Service state may not be initialized.
  • If User Account Control is enabled, run the .msp update files from an elevated command prompt.
  • You must have System Administrator rights on the database instances for the Operational Database and Data warehouse to apply updates to these databases.
  • To enable the web console fixes, add the following line to the %windir%\Microsoft.NET\Framework64\v2.0.50727\CONFIG\web.config file:

    <machineKey validationKey="AutoGenerate,IsolateApps" decryptionKey="AutoGenerate,IsolateApps" validation="3DES" decryption="3DES"/>


    Note Add the line under the <system.web> section, as described in the following article in the Microsoft Knowledge Base:

    911722 You may receive an error message when you access ASP.NET Web pages that have ViewState enabled after you upgrade from ASP.NET 1.1 to ASP.NET 2.0
  • The fix for the data warehouse BULK insert commands time out issue described in Update Rollup 1 for System Center 2012 R2 Operations Manager adds a registry key that can be used to set the time-out value (in seconds) for the data warehouse BULK insert commands. These are the commands that insert new data into the data warehouse.

    Note This key must be manually added on any management server on which you want to override the default BULK insert command time out.

    Registry location:HKEY_LOCAL_MACHINE\Software\Microsoft\Microsoft Operations Manager\3.0\Data Warehouse
    DWORD name: Bulk Insert Command Time Out Seconds
    DWORD Value: 40

    Note Set this value in seconds. For example, for a 40-second time-out, set this value to 40.

Supported installation order
We recommend that you install this update rollup package by following these steps in the given order:
  1. Install the update rollup package on the following server infrastructure:
    • Management server or servers
    • Gateway servers
    • Web console server role computers
    • Operations console role computers


  2. Apply SQL scripts (see installation information).
  3. Manually import the management packs.
  4. Apply the agent update to manually installed agents, or push the installation from the Pending view in the Operations console.


Note If the Connected MG/Tiering feature is enabled, you should first update the top tier of the Connected MG/Tiering feature.
Operations Manager update
To download the update rollup package and extract the files that are contained in the update rollup package, follow these steps:
  1. Download the update packages that Microsoft Update provides for each computer. Microsoft Update provides the appropriate updates according to the components that are installed on each computer. Or download from the Microsoft Download Catalog.
  2. Apply the appropriate MSP files on each computer.

    Note MSP files are included in the update rollup package. Apply all MSP files that relate to a specific computer. For example, if the web console and console roles are installed on a management server, apply the MSP files on the management server. Apply one MSP file on a server for each specific role that the server holds.

  3. Execute the flowing Datawarehouse SQL script on Datawarehouse Server against OperationsManagerDW database:

    UR_Datawarehouse.sql


    Note This script is located in the following path:

    %SystemDrive%\Program Files\System Center 2012 R2\Operations Manager\Server \SQL Script for Update Rollups

  4. Execute the following Database SQL script on the Database server against the OperationsManagerDB database:

    Update_rollup_mom_db.sql

  5. Import the following management packs:
    • Microsoft.SystemCenter.TFSWISynchronization.mpb. This has the following dependency:
      • Microsoft.SystemCenter.AlertAttachment.mpb. This should be installed from the System Center Operations Manager 2012 R2 media.
      • Microsoft.SystemCenter.Visualization.Library.mpb


    • Microsoft.SystemCenter.Visualization.Component.Library.mpb
    • Microsoft.SystemCenter.Visualization.Library.mpb
    • Microsoft.SystemCenter.Advisor.mpb
    • Microsoft.SystemCenter.Advisor.Internal.mpb
    • Microsoft.SystemCenter.2007.mp
    • Microsoft.SystemCenter.Advisor.Resources.LANGUAGECODE_3LTR.mpb

For information about how to import a management pack from a disk, see the How to Import an Operations Manager Management Pack topic on the Microsoft TechNet website.

Note Management packs are included in the Server component updates in the following path:

%SystemDrive%\Program Files\System Center 2012 R2\Operations Manager\Server\Management Packs for Update Rollups

UNIX/Linux Management Pack update
To install the updated monitoring packs and agents for UNIX and Linux operating systems, follow these steps:

  1. Apply Update Rollup 5 to your System Center 2012 R2 Operations Manager environment.
  2. Download the updated management packs for System Center 2012 R2 from the following Microsoft website:


  3. Install the management pack update package to extract the management pack files.
  4. Import the updated management pack for each version of Linux or UNIX that you are monitoring in your environment.
  5. Upgrade each agent to the latest version by using either the Update-SCXAgent Windows PowerShell cmdlet or the UNIX/Linux Agent Upgrade Wizard in the Administration pane of the Operations Console.


↑ Back to the top


Files that are updated in this update rollup
The following is a list of files that changed in this update rollup. If you do not have all previous update rollups installed, files other than those that are listed here may also be updated. For a complete list of files that are updated, refer to the "Files Updated in this Update Rollup" section of all update rollups that were released after your current update rollup.
Files that are updatedVersionSize
Microsoft.EnterpriseManagement.DataAccessLayer.QueryCache.dll7.5.3079.3542.14 MB
Microsoft.EnterpriseManagement.DataAccessLayer.dll7.5.3079.3542.40 MB
Microsoft.Mom.UI.Components.dll7.1.10226.10645.87 MB
Microsoft.EnterpriseManagement.UI.Authoring.dll7.1.10226.10649.44 MB
Microsoft.Mom.UI.common.dll7.1.10226.10642.19 MB
Microsoft.EnterpriseManagement.Presentation.Controls.dll7.1.10226.10641.70 MB
monitoringportal.xap7.1.10226.10643.92 MB
update_rollup_mom_db.sql7.1.10226.106490.4 KB
UR_DataWarehouse.sql7.1.10226.1064111 KB
MonAgentTraceTMF.CAB7.1.10226.10641.64 MB

↑ Back to the top


Keywords: kb, atdownload, kbsurveynew, kbexpertiseinter, kbnotautohotfix, kbfix, kbqfe

↑ Back to the top

Article Info
Article ID : 3051169
Revision : 2
Created on : 4/9/2020
Published on : 4/9/2020
Exists online : False
Views : 323