Issue: In almost all cases, when this event is logged the event is harmless. The event occurs because a name change event was generated after the printer was deleted. If this is the case, no action is required, and redirected printing should continue to function normally.
The one instance where a 0x5be (or 0x5D6 if SP2 is installed) will be logged and redirected printing will be affected is when you are using the Citrix Metaframe add-on. ICA clients that connect with unknown printer drivers will also generate an 1103 0x5be (or 0x5D6 if SP2 is installed). To resolve this type of 0x5be (or 0x5D6 if SP2 is installed), use ICA specific steps in the following Microsoft Knowledge Base article:
214593 Windows Terminal Server with Metaframe ICA Client Cannot Autocreate Some Printers
0x2c6
This error can be caused by a failure in communications between the user-mode component and Rdpdr.sys. This error may result in printer redirection being disabled for the associated session. The user should log off and on again. If this does not resolve the problem, Terminal Services should be uninstalled and reinstalled.
0x376
This problem occurs because the Terminal Services Device Redirector did not install properly. To resolve this issue, uninstall and reinstall Terminal Services.
0x384
This error indicates that the program desktop in the user-mode component was not set up correctly. This error may result in printer redirection being disabled for the associated session. The user should log off and on again. If this does not resolve the problem, Terminal Services should be uninstalled and reinstalled.
0x394
This error occurs when the IOCTL buffer cannot be resized. This error may result in printer redirection being disabled for the associated session. The user should log off and on again. If this does not resolve the problem, Terminal Services should be uninstalled and reinstalled.
0x3c5
This error occurs when the IOCTL buffer cannot be resized. This error may result in printer redirection being disabled for the associated session. The user should log off and on again. If this does not resolve the problem, Terminal Services should be uninstalled and reinstalled.
0x4f6
This error can be caused by a failure in communications between the user-mode component and Rdpdr.sys. This error may result in printer redirection being disabled for the associated session. The user should log off and on again. If this does not resolve the problem, Terminal Services should be uninstalled and reinstalled.
0x50a
This error can be caused by a failure in communications between the user-mode component and Rdpdr.sys. This error may result in printer redirection being disabled for the associated session. The user should log off and on again. If this does not resolve the problem, Terminal Services should be uninstalled and reinstalled.
0xCa