When you start the Microsoft Message Queuing Triggers service from the Service Control panel, you may receive the following error message:
Event 1Event 2
The MSMQ Triggers service returned service specific error 2147500037.
Also, events that are similar to the following events may be present in the application event log:Event 1
Source: MSMQ Triggers
Category: None
Event: 64636
MACHINE=(null);
OBJECT=MSMQTriggerService;
CATEGORY=3;
EVENTID=-900;
THREADID=347
MSMQ Trigger Service has failed whilst validating the required registry
entries and queues. The error message was failed to create the queue
MSMQServer\PRIVATE$\MSMQTriggersNotifications. The HRESULT from MSMQ was
(C00E0025). The HRESULT was (80004005).
Source: MSMQ Triggers
Category: None
Event: 65535
MACHINE=(null);
OBJECT=MSMQTriggerService;
CATEGORY=3;
EVENTID=-1;
THREADID=347
The MSMQTriggerService has failed to initialize the pool of trigger
monitors. The service is being shutdown. No trigger processing will occur.