Software Metering rules do not apply when targeted to secondary sites in System Center Configuration Manager


View products that this article applies to.

Summary

In System Center Configuration Manager, when you set the Site Code of a Software Metering rule to a secondary site, that rule will not be applicable to any clients.

This is expected behavior.

↑ Back to the top


More Information

SMS 2003 Advanced Clients and Configuration Manager clients within a secondary site boundary also obtain policy from the primary site’s site database. If the Site Code of a Software Metering rule is set to a secondary site, no policy will be generated for that rule, so that no clients will receive that rule. You must set the “Site Code” of a rule to a primary site’s site code to make it assigned to clients.

↑ Back to the top