DiskRaid.exe does not populate "Array Lun number" correctly


View products that this article applies to.

Symptoms

You have a Virtual Disk Service (VDS) 3.0 hardware provider installed that supports “LUN NUMBER SUPPORTED” feature on a computer (HOST) that is running Windows Server 2008 R2 or Windows 7.

When you run the Diskraid command to list the LUNs on the subsystem the right most column shows the array assigned LUN number. After selecting a HOST exposed LUN (NT Disk) and unmask it with /uninstall option. The disk will be uninstalled from the host system and then mask setting applied.

If you now execute the command “List luns” the selected LUN will now not show the array assigned LUN Number.

↑ Back to the top


Cause

This is a bug as DiskRAID doesn’t show the output correctly.

↑ Back to the top


Workaround

Exit and Restart DiskRAID to view detail LUN for the selected Lun, it does show the Lun number correctly.

↑ Back to the top


More Information

DiskRAID.exe is a scriptable, command-line utility that configures and manages hardware RAID subsystems. This utility can interact with any storage hardware that is accompanied by a VDS hardware provider.

DiskRAID: http://technet.microsoft.com/en-us/library/cc770763(WS.10).aspx

↑ Back to the top


Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

↑ Back to the top


Keywords: kb