Notice: This website is an unofficial Microsoft Knowledge Base (hereinafter KB) archive and is intended to provide a reliable access to deleted content from Microsoft KB. All KB articles are owned by Microsoft Corporation. Read full disclaimer for more details.

Network switch with full-duplex incompatible with half-duplex network interface cards (NICs)


View products that this article applies to.

Symptoms

Clients cannot log on to the domain controllers. Additional NetBIOS traffic problems are:
  • Loss of connectivity between servers resulting in servers being unavailable in Server Manager.
  • Trust relationships failing to work and failing to be created.
  • Other connectivity where sessions for two-way are required.
The primary domain controller (PDC) forces a browsing election every 12 minutes and generates one of the following events:
Event ID: 8003

Description: The master browser has received a server announcement from the Windows NT client that believes that it is the master browser for the domain on transport (NetBT). The master browser is stopping or an election is being forced.

Event ID: 8003

Description: The master browser has received a server announcement from the <computer_name> that believes that it is the master browser for the domain on transport (NetBT). The master browser is stopping or an election is being forced."
The client computer is located in a different subnet, and UDP 137 and 138 broadcasts are not being forwarded.

↑ Back to the top


Cause

This problem occurs when network logon validation is prevented over a network switch.

The network switch prevents the server from authenticating the client. The two-way communication session necessary for logon validation is prevented. The Windows-based client computer that cannot successfully communicate with the Windows-based server acting as the subnet master browser may cause a browser election, which causes the event ID 8003 error to be registered on the PDC.

↑ Back to the top


Resolution

Network switches and server network interface cards (NICs) have to have the duplex settings matched for NetBIOS communication to function properly. Both need to be either full-duplex or half-duplex, but they cannot be mismatched.

Browser elections resolution: Some OEM FDDI adapters configured for full-duplex might be incompatible with some network switches. When the OEM FDDI cards were replaced with full-duplex cards, the browsing elections went away.

↑ Back to the top


More information

Troubleshooting Steps

  1. Removed any unnecessary protocols besides TCP/IP and attempt to log on.
  2. Put the client and the server on a passive hub and attempt to log on. This eliminates the network switch from the logon process; if communication resumes, it points to network switch configuration issues.
  3. Reset switch, restart the client, and test the connectivity.
  4. Ping across the switch by IP address from client to server or server to client. This may work in spite of connectivity issues; ping is broadcast based and not a session controlled three-way communication.
  5. Check the switch configuration settings for duplex settings and also check the server's NIC for duplex settings. If the network switch and server NIC are mismatched with one on full-duplex and the other half-duplex, the three-way communication will be prevented and NetBIOS connectivity will fail.
  6. Replaced the half-duplex NIC on the server with a full-duplex and test. This may be required to avoid the mismatch if the network switch and/or the server's NIC are not configurable. It is a more dramatic step than reconfiguring devices, but has proven to be a sound solution. Resetting the server NIC to half-duplex will lose communication again.

↑ Back to the top


Keywords: KB224131, kbprb, kbhardware

↑ Back to the top

Article Info
Article ID : 224131
Revision : 2
Created on : 1/21/2008
Published on : 1/21/2008
Exists online : False
Views : 454